5. The control mechanism (electrical) malfunctions, such as: relay malfunction, poor or damaged button contact, incorrect installation of electromagnet, incorrect connection of motor phase wire, etc., which cause hydraulic components to malfunction or program errors.
2) The oil blocking method, such as blocking the oil ports of valve components and cylinder oil ports, can diagnose whether these hydraulic components are leaking or failing.
4. Replace the oil regularly. The oil tank must be cleaned once before replacing the new oil. When the system is dirty, it can be cleaned with kerosene. After draining, inject new oil.
Control the temperature of the hydraulic system. Excessive oil temperature will reduce the service life of the seal. Long-term high oil temperature will cause permanent deformation of the seal, or even complete failure.
Nowadays, various publicity platforms such as Internet+, e-commerce, and WeChat business are highly concerned. The gantry shear industry can also learn from it. Expand the equipment publicity platform, broaden the equipment marketing channels, and increase the market awareness of gantry shears. , Establish a brand image.